We recently upgrade one of our project from SharePoint 2007 to
SharePoint 210. In that project we user event handler for list. In
ItemAdding event we use to create new site which takes times for
creation. So we use SPLongOperation to handle it but in SharePoint 2010
its same code gives error for "Object reference null" for
SPLongOperation being statement.
So we had following workaround for this problem.
Create Web Part with following Code and add this web part to publishing Page
protected override void CreateChildControls(){
if (this.Page.Request.QueryString["Processid"] != null)
{
using (SPLongOperation ctx = new SPLongOperation(this.Page))
{
try
{
ctx.LeadingHTML = "Please wait while your operation is being executed.";
ctx.TrailingHTML = "Site is being created. Please wait....";
ctx.Begin();
System.Threading.Thread.Sleep(5000);
string eid = this.Page.Request.QueryString["Processid"].ToString();
int count = 1;
while (true)
{
using (SPWeb web = SPContext.Current.Site.OpenWeb(SPContext.Current.Web.ID))
{
if (web.Properties[eid].ToString() != "Completed" && count < 18)
{
System.Threading.Thread.Sleep(5000);
count++;
}
else
break;
}
}
ctx.End(this.Page.Request.QueryString["h"].ToString());
}
catch (Exception ex)
{
this.lbl.Text = ex.Message.ToString() + Environment.NewLine + ex.StackTrace.ToString() ;
}
}
}
}
In event handler modify ItemAdding event as follows
public override void ItemAdding(SPItemEventProperties properties)
{
base.ItemAdding(properties);
string guid
= string.Format("ProcessId{0}_{1}", DateTime.Now.ToString("MMddyyyy"), Guid.NewGuid().ToString());
Thread thread = new Thread(() => FunctionName(properties,guid));
thread .Start();
properties.Status = SPEventReceiverStatus.CancelNoError;
properties.Cancel = true;
SPUtility.Redirect({Url of page on which out put above webpart}, SPRedirectFlags.Default, _currentContext,string.Format ("Processid={0}&h={1}",guid , properties.RelativeWebUrl));
}
Hope this work for you also
So we had following workaround for this problem.
Create Web Part with following Code and add this web part to publishing Page
protected override void CreateChildControls(){
if (this.Page.Request.QueryString["Processid"] != null)
{
using (SPLongOperation ctx = new SPLongOperation(this.Page))
{
try
{
ctx.LeadingHTML = "Please wait while your operation is being executed.";
ctx.TrailingHTML = "Site is being created. Please wait....";
ctx.Begin();
System.Threading.Thread.Sleep(5000);
string eid = this.Page.Request.QueryString["Processid"].ToString();
int count = 1;
while (true)
{
using (SPWeb web = SPContext.Current.Site.OpenWeb(SPContext.Current.Web.ID))
{
if (web.Properties[eid].ToString() != "Completed" && count < 18)
{
System.Threading.Thread.Sleep(5000);
count++;
}
else
break;
}
}
ctx.End(this.Page.Request.QueryString["h"].ToString());
}
catch (Exception ex)
{
this.lbl.Text = ex.Message.ToString() + Environment.NewLine + ex.StackTrace.ToString() ;
}
}
}
}
In event handler modify ItemAdding event as follows
public override void ItemAdding(SPItemEventProperties properties)
{
base.ItemAdding(properties);
string guid
= string.Format("ProcessId{0}_{1}", DateTime.Now.ToString("MMddyyyy"), Guid.NewGuid().ToString());
Thread thread = new Thread(() => FunctionName(properties,guid));
thread .Start();
properties.Status = SPEventReceiverStatus.CancelNoError;
properties.Cancel = true;
SPUtility.Redirect({Url of page on which out put above webpart}, SPRedirectFlags.Default, _currentContext,string.Format ("Processid={0}&h={1}",guid , properties.RelativeWebUrl));
}
Hope this work for you also
No comments: